Aim: This study aimed to investigate the effect of the two impression techniques on the final accuracy of implant casts. Materials & Methods: In this study 4 DIO implant analogues are embedded on a laboratory model & were evaluated with using two impression techniques. In close tray impression technique, it was used of special impression coping of close tray, but in Acrylic technique , it was made Acrylic pattern for any abutments & are connected with duralay acryl. 4final casts are made with each of techniques. The accuracy of final casts was evaluated in 3 dimensions. Measurment of determinate distance was done by CMM with the accuracy of 0.1 micron & the size difference in the final casts with a laboratory model were analyzed by SPSS statistical ware. Results: There was no differences in two techniques on dimension accuracy of the final casts accuracy. Conclusions: The implant impression by Jig technique is as simple as Close tray technique & it is more accurate than Close tray technique in complex cases are preferred.
کلید واژگان :Implant, impression, acryle
ارزش ریالی : 100000 ریال
با پرداخت الکترونیک
جزئیات مقاله
- کد شناسه : 7155350600210638
- سال انتشار : 2017
- نوع مقاله : چکیده مقاله پذیرفته شده در کنفرانس ها(فایل کامل مقاله بارگزاری گردد)
- زبان : انگلیسی
- محل پذیرش : FDI 2107 World Dental Congress
- برگزار کنندگان : Spain- Madrid
- تاریخ ثبت : 1398/01/05 13:56:42
- ثبت کننده : سمیرا جمالی
- تعداد بازدید : 282
- تعداد فروش : 0